全新原装401HDV-64D2Y日立压缩机详细内容
全新原装401HDV-64D2Y日立压缩机配件 Accessories Of Compressor
NO. 名称 Parts Name 数量 Qty 代号 Drawing NO. 备注 Remarks
1 防振胶垫 Rubber Grommet B 4 TP1-102 标准部件
Standard Parts
2 防振胶座 Rubber Grommet A 4 TP1-103
3 支撑螺柱 Bolt 4 TP1-101
4 垫圈 Washer 4 TP1-104
5 M6螺母 M6 Screw Nut 4 GB41-86-M6
6 M8螺母 M8 Screw Nut 4 GB41-86-M8
7 弹性垫圈 Spring Washer 4 GB93-87-6
8 温控器挡板 Thermostat Holder 1 TP1-105 选择部件
Option Parts
9 排气温控器 Discharge Thermostat 1 TP1-106
10 热油器 Crankcase Heater 1 TP1-110
3. 401HDV-64D2Y日立压缩机使用条件范围 Operating Conditions
蒸发温度 Evaporating Temp. -15~15℃
排气温度 Discharge Temp. (冷凝温度+15℃)~120℃以下
(Condensing Temp.+15℃)~120℃ Max.
绕组温度 Winding Temp. 120℃以下 Max.
压缩机外壳温度 Shell Temp. 115℃以下 Max.
吸气压力 Suction Pressure 0.1~0.7MPa (起动、除霜等短时间运转除外;Except the short period such as start,defrost)
排气压力 Discharge Pressure 1.1~2.8MPa
压力比 Pressure Ratio 2~7.5 (起动、除霜等短时间运转除外;Except the short period such as start,defrost)
起动时的压力差
Pressure Difference At Starting 排气压力-吸气压力≤0.30MPa
D.P.-S.P. less than 0.30MPa
启停周期 On/Off Period 周期为10分钟以上,停止时间必须3分钟以上
10 minutes min/cycle,OFF should be over 3 minutes
较低油量 Minimum Oil Charge 400ml Min.
异常升压/降压
Abnormal Press. Rise/Drop 上升:3.0MPa以下 Rise:3.0MPa Max.
下降:0.2MPa以上 Drop:0.2MPa Min.
配管(铜管)应力
Copper Piping Stress 启动时:50MPa以下 Start:50MPa Max.
运转时:10MPa以下 Run:10MPa Max.
冷媒水分含量Refrigerant Moisture Level 60ppm以下 Max.
系统固体杂质含量Solid Impurities Level 100mg以下 Max.
运转倾斜角度 Tilt In Operation 压缩机倾斜较大5°以内 5 deg. Max.
※ 401HDV-64D2Y压缩机其他注意事项 Remarks:
1. 压缩机在去除吸、排气接头盖后,请勿放置10分钟以上;
Installation shall be completed within 10 minutes after removing the caps of suction and discharge tube.
2. 请勿压缩空气;
Do not compress air.
3. 在真空状态下请勿通电;
Do not energize under vacuumed condition.
4. 热泵系统必须在压缩机底部安装油加热器(40~80W,220V);
Crankcase heater is require if the refrigeration system is heat pump.
5. 请勿反向旋转;
Do not reverse rotate.
6. 运转时,各相间的电压偏差应在额定电压的3%以内;
Voltage (run):Voltage deviation each phase shall be within 3% of the rated voltage.
7. 成箱压缩机包装件的叠放堆码极限为2箱,装卸过程中严禁翻滚;
Pile limits 2 pallet.Tumbling is forbidden during handling.
8. 向压缩机充油或冷媒时,必须从排气侧进行;
Charge oil or refrigerant from the discharge pipe.
9. 压缩机的接地装置应*与制冷器具的接地装置连接;
The compressor’s ground should be connected with that of refrigeration system permanently and firmly.