全新原装401HDV-64D2Y日立压缩机配件 Accessories Of Compressor NO. 名称 Parts Name 数量 Qty 代号 Drawing NO. 备注 Remarks 1 防振胶垫 Rubber Grommet B 4 TP1-102 标准部件 Standard Parts 2 防振胶座 Rubber Grommet A 4 TP1-103 3 支撑螺柱 Bolt 4 TP1-101 4 垫圈 Washer 4 TP1-104 5 M6螺母 M6 Screw Nut 4 GB41-86-M6 6 M8螺母 M8 Screw Nut 4 GB41-86-M8 7 弹性垫圈 Spring Washer 4 GB93-87-6 8 温控器挡板 Thermostat Holder 1 TP1-105 选择部件 Option Parts 9 排气温控器 Discharge Thermostat 1 TP1-106 10 热油器 Crankcase Heater 1 TP1-110 3. 401HDV-64D2Y日立压缩机使用条件范围 Operating Conditions 蒸发温度 Evaporating Temp. -15~15℃ 排气温度 Discharge Temp. (冷凝温度+15℃)~120℃以下 (Condensing Temp.+15℃)~120℃ Max. 绕组温度 Winding Temp. 120℃以下 Max. 压缩机外壳温度 Shell Temp. 115℃以下 Max. 吸气压力 Suction Pressure 0.1~0.7MPa (起动、除霜等短时间运转除外;Except the short period such as start,defrost) 排气压力 Discharge Pressure 1.1~2.8MPa 压力比 Pressure Ratio 2~7.5 (起动、除霜等短时间运转除外;Except the short period such as start,defrost) 起动时的压力差 Pressure Difference At Starting 排气压力-吸气压力≤0.30MPa D.P.-S.P. less than 0.30MPa 启停周期 On/Off Period 周期为10分钟以上,停止时间必须3分钟以上 10 minutes min/cycle,OFF should be over 3 minutes 较低油量 Minimum Oil Charge 400ml Min. 异常升压/降压 Abnormal Press. Rise/Drop 上升:3.0MPa以下 Rise:3.0MPa Max. 下降:0.2MPa以上 Drop:0.2MPa Min. 配管(铜管)应力 Copper Piping Stress 启动时:50MPa以下 Start:50MPa Max. 运转时:10MPa以下 Run:10MPa Max. 冷媒水分含量Refrigerant Moisture Level 60ppm以下 Max. 系统固体杂质含量Solid Impurities Level 100mg以下 Max. 运转倾斜角度 Tilt In Operation 压缩机倾斜较大5°以内 5 deg. Max. ※ 401HDV-64D2Y压缩机其他注意事项 Remarks: 1. 压缩机在去除吸、排气接头盖后,请勿放置10分钟以上; Installation shall be completed within 10 minutes after removing the caps of suction and discharge tube. 2. 请勿压缩空气; Do not compress air. 3. 在真空状态下请勿通电; Do not energize under vacuumed condition. 4. 热泵系统必须在压缩机底部安装油加热器(40~80W,220V); Crankcase heater is require if the refrigeration system is heat pump. 5. 请勿反向旋转; Do not reverse rotate. 6. 运转时,各相间的电压偏差应在额定电压的3%以内; Voltage (run):Voltage deviation each phase shall be within 3% of the rated voltage. 7. 成箱压缩机包装件的叠放堆码极限为2箱,装卸过程中严禁翻滚; Pile limits 2 pallet.Tumbling is forbidden during handling. 8. 向压缩机充油或冷媒时,必须从排气侧进行; Charge oil or refrigerant from the discharge pipe. 9. 压缩机的接地装置应*与制冷器具的接地装置连接; The compressor’s ground should be connected with that of refrigeration system permanently and firmly.